Laboratory analytics is the use of data that laboratories already generate, from the laboratory information system, instruments, and quality records, to measure performance and decide where to improve. It turns questions such as “why are emergency results slow on weekday mornings?” into answers that can be tested and tracked. Published examples show what is possible: a Lean Six Sigma project in a Turkish teaching hospital reduced the turnaround time for urgent tests from 68 to 59 minutes and cut error-prone process steps from 30 percent to 3 percent, and a hospital in Bangkok reported a 47.6 percent decrease in mean turnaround time after combining automation with informatics.
Clinical laboratories record a timestamp at nearly every step of a specimen’s journey, along with results, reruns, rejections, and instrument events. Much of that information is used only to produce a report and then forgotten. This article explains what laboratory analytics measures, how dashboards and key performance indicators work in practice, what published studies have achieved, and how laboratories can start using their data more effectively.
What Laboratory Analytics Means
Laboratory analytics covers several related activities. Descriptive analytics summarizes what has happened, such as how many tests were run or how long they took. Diagnostic analytics looks for causes, for example by breaking turnaround time into collection, transport, receipt, analysis, and verification. Monitoring analytics tracks performance continuously, often through dashboards, so that problems can be spotted early.
The raw material usually comes from laboratory information systems, which record when a test was ordered, collected, received, resulted, and verified. Combined with instrument logs and quality control data, these records describe how the laboratory actually works, which may differ from how it is supposed to work.
Analytics is part of a broader shift toward the digital laboratory, in which data flows electronically and decisions are based on evidence rather than impression.
Key Performance Indicators That Matter

Laboratories can measure many things, but a small set of key performance indicators, or KPIs, usually tells the most important story.
Turnaround time (TAT). The time from order or collection to a verified result is the measure clinicians notice most. It is most useful when split into phases so that delays can be located.
Specimen rejection and recollection rates. Rejected specimens delay care and frustrate patients. Tracking the reasons, such as hemolysis, clotting, or labeling errors, points to where training or process changes are needed. Specimen rejection criteria in clinical laboratories covers the most common causes.
Critical value notification time. How quickly life-threatening results reach a responsible clinician is a direct patient safety measure.
Quality control and proficiency testing performance. Trends in quality control data can reveal instrument drift before it affects patient results.
Test utilization. Patterns of ordering, including repeat tests within short intervals, can show where testing could be more appropriate. Laboratory test utilization explores this topic in more depth.
Workload and productivity. Tests per staff hour and volume by time of day help align staffing with demand.
Turning Data Into Dashboards

A dashboard brings KPIs together in a visual form that staff and managers can check quickly. A well-documented example comes from South Africa’s National Health Laboratory Service. In a 2020 article in the African Journal of Laboratory Medicine, Cassim and colleagues described an interactive weekly turnaround time dashboard built from the service’s corporate data warehouse. In one sample week, the dashboard reported on 45,599 samples, and it was rolled out to all of the service’s testing laboratories.
The authors made an important point about how turnaround time should be reported. Because TAT data are skewed, with a long tail of slow results, reporting only the mean can mask good performance while concealing poor efficiency. Their dashboard therefore added the median, the 75th percentile, and the percentage of samples completed within a target time. The authors also noted that a dashboard does not in itself produce improvement. It shows where to look, and people still have to act.
Good dashboards share a few features: they show a small number of meaningful measures, compare performance with clear targets, are updated often enough to be useful, and are visible to the teams who can change the results.
Using Analytics to Reduce Turnaround Time

Analytics is most powerful when combined with a structured improvement method. In a study published in the Journal of Clinical Laboratory Analysis, Inal and colleagues applied Lean Six Sigma to the central laboratory of a large teaching hospital in Turkey. By measuring each step and removing activities that added no value, the team reduced turnaround time for urgent tests from 68 to 59 minutes. Process steps prone to medical error or biohazard fell from 30 percent to 3 percent, and the number of mislabeled tubes dropped from 250 to 300 a day to 25 to 30 a day.
A second example comes from Lerdsin Hospital in Bangkok, described in the British Journal of Biomedical Science in 2023. After introducing an automated system with informatics, the hospital’s mean turnaround time fell from more than 2.5 hours to under 1.5 hours, a 47.6 percent decrease, and outpatient turnaround time improved by more than 54 percent. Turnaround data drawn from the laboratory information system before and after go-live made it possible to show the change clearly.
These studies show a common pattern: measure the current process, find the steps that cause delay, change the process, and use the same data to confirm that the change worked. The pre-analytical phase in laboratory testing is often where the largest delays hide, because transport and receipt are harder to see than analysis.
Improving Quality and Patient Safety
Analytics also supports quality beyond speed. Monitoring quality control results over time can reveal gradual shifts that individual daily checks may miss. Tracking delta checks and repeat testing can highlight possible specimen mix-ups. Reviewing error reports by category shows whether a problem is isolated or systemic.
These uses connect directly to diagnostic quality assurance and to the continuous improvement expected by accreditation bodies. They also matter for patients, because laboratory results influence a large share of clinical decisions, as how laboratory data drives accurate medical decisions explains.
Building an Analytics Culture in the Laboratory

Technology is only part of the picture. Laboratories that use data well tend to have a few habits in common:
- Start with a question. Choose one problem that matters, such as emergency department turnaround, rather than trying to measure everything at once.
- Check the data. Timestamps can be missing or recorded inconsistently. Cleaning and validating data before drawing conclusions avoids chasing false problems.
- Share results with staff. Bench staff often know why delays happen. Showing them the data invites solutions and builds ownership.
- Pair data with action. Agree in advance what will be done when a measure falls below target.
- Build skills. Training staff in basic data analysis and visualization creates capacity within the team and opens new career paths, including roles in laboratory informatics.
Artificial intelligence may expand what analytics can do, from predicting workload to flagging unusual result patterns. As AI in laboratory medicine discusses, these tools still depend on good data and on professionals who understand what the results mean.
Conclusion
Laboratory analytics turns the data laboratories already collect into a practical tool for improvement. Published studies show measurable gains when data is combined with structured process change, from shorter turnaround times to fewer error-prone steps, and dashboards make performance visible to the people who can act on it.
The most important lessons are simple. Measure what matters, report it honestly, including the slow tail and not just the average, and use the results to guide action. Laboratories that build these habits will be better placed to deliver fast, accurate results with the staff and resources they have.
Frequently Asked Questions
What is laboratory analytics?
Laboratory analytics is the use of data from laboratory information systems, instruments, and quality records to measure performance, find the causes of problems, and track improvement. Common uses include monitoring turnaround time, specimen rejection, quality control trends, and test utilization.
What are the most important KPIs for a clinical laboratory?
Widely used key performance indicators include turnaround time, specimen rejection and recollection rates, critical value notification time, quality control and proficiency testing performance, test utilization, and workload per staff hour.
Why should turnaround time not be reported only as an average?
Turnaround time data are usually skewed by a small number of very slow results. A 2020 study of a South African laboratory dashboard noted that reporting only the mean can mask good performance while concealing poor efficiency, so percentiles and the share of results completed within target are more informative.
Can data analytics really reduce turnaround time?
Yes, when it is combined with process change. A Lean Six Sigma project in a Turkish teaching hospital reduced urgent test turnaround from 68 to 59 minutes, and a Bangkok hospital reported a 47.6 percent decrease in mean turnaround time after introducing automation with informatics.
How can a small laboratory start using analytics?
Start with one important question, use existing laboratory information system reports, check the data for accuracy, share results with staff, and agree on actions when performance falls below target. Simple spreadsheets or built-in system reports are often enough to begin.
Bio-Reach is a non-profit organization dedicated to advancing Laboratory Medicine through advocacy, education, and global collaboration. To learn more or get involved, visit bio-reach.org.